TS Series

Q1.Pump does not start.

Cause Remedy
No power supply. Connect the electricity supply.
Too low/high voltage. Check if supply voltage is within ± 10%.
Seized-up pump. Place a screwdriver against the shaft end of the motor to check it the rotor will spin freely, and contact your pump supplier.

Remark: before operation, turn off power switch first.

Q2.Pump cuts out during operation.

Cause Remedy
Seized-up pump. Same as above.
Overloaded motor. Turn off the power supply and restart or contact your pump supplier.
Poor water supply. Check if pump suction inlet is blocked.
Overheating due to excessive water temperature. 1. Wait till water temp. cool down before restarting the pump.
2. For rapid restart, fill cold water to the chamber to quickly cool down the liquid temp.

Remark: before operation, turn off power switch first.

Q3.Electric shock.

Cause Remedy
Ineffective grounding. Reactivate grounding.

Remark: before operation, turn off power switch first.

Q4.Pump runs normal but with very low discharge flow.

Cause Remedy
3-phase motor runs in wrong rotation. Switch any of the 2 wires from motor terminal to correct rotation.
Poor water supply. Check if water supply is adequate and if the suction pipe is blocked.

Remark: before operation, turn off power switch first.