Constant Pressure Inverter Control System

Applications

Apartment buildings, houses, villa water supply, factories, water supply systems, drinking water systems, RO water treatment equipment, supermarkets, motels, SPA, etc.

Product Features

The pump will start smoothly when water is consumed. The inverter controller has a pressure sensor to detect down-stream pressure and adjust the motor speed to keep it at the required psi.

Constant and stable pressure control

The pump will maintain a constant operating pressure at the pressure setting. This ensures a stable water supply even though occasionally the output .ow is over the capacity.

Dry-run protection

The pump will automatically shut down to protect against dry running. Once the pump starts to operate, the pressure sensor will automatically detect the pressure limit.

Automatic stop when flow stops

The pump will automatically cycle down as water usage decreases.

Pressure compensation for pipeline leaks

Should the down steam pressure drop due to leaks in the piping system, the microcomputer will detect the pressure loss automatically and operate the pump to maintain the pressure setting limit.

Single or parallel unit operation

Parallel operation: When water usage is low, one unit will begin to operate until the water usage increases, when it can no longer handle the required water pressure, the other unit will start functioning in parallel. The duplex unit will switch to single unit operation automatically with the decrease in water demand.

Interchangeable operation

When a pump has operated through the preset interval (adjustable at 0-24 hours) the system will automatically switch to the other unit. This cycle will continue through time.

Operation Condition

Ambient temperature:Max. +40°C

Liquid temperature:+4°C~+75°C

Suitable liquids:Potable water or other clean, thin or non-aggressive liquids

System Pressure:Max.10kg/cm²

Inlet pressure: Lower than the constant pressure setting limit (see page 03~08)

TPHICx2

Compare Products (multiple options available)

Type
TPH2T2KICx2
TPH2T3KICx2
TPH2T4KICx2
TPH2T5KICx2
TPH2T6KICx2
TPH4T2KICx2
TPH4T3KICx2
TPH4T4KICx2
TPH4T5KICx2
TPH4T6KICx2
TPH8T2KICx2
TPH8T3KICx2
TPH8T4KICx2
TPH8T5KICx2
TPH12T2KICx2
TPH12T3KICx2
TPH12T4KICx2
TPH25T2KICx2
TPH25T3KICx2
TPH25T4KICx2
TPH25T5KICx2
TPH25T6KICx2
Type Inverter Controller Output Power
(HP)
Phase
(Ø)
Volts
(V)
No-Fuse Breaker Pre-set Pressure
(kg/cm²)
Inlet
(in.)
Outlet
(in.)
Nominal Set Head
(M)
Nominal Set FLow
(L/min)
TPH2T2KICx2 1x2 13 200-240V200-240V or 380-440V 2.0 1 2 20 60
TPH2T3KICx2 1x2 13 200-240V200-240V or 380-440V 3.0 1 2 30 60
TPH2T4KICx2 1x2 13 200-240V200-240V or 380-440V 4.0 1 2 40 60
TPH2T5KICx2 1x2 13 200-240V200-240V or 380-440V 5.0 1 2 50 60
TPH2T6KICx2 1x2 13 200-240V200-240V or 380-440V 6.0 1 2 60 60
TPH4T2KICx2 1x2 13 200-240V200-240V or 380-440V 2.0 2 20 120
TPH4T3KICx2 1x2 13 200-240V200-240V or 380-440V 3.0 2 30 120
TPH4T4KICx2 2x2 13 200-240V200-240V or 380-440V 4.0 2 40 120
TPH4T5KICx2 2x2 13 200-240V200-240V or 380-440V 5.0 2 50 120
TPH4T6KICx2 2x2 13 200-240V200-240V or 380-440V 6.0 2 60 120
TPH8T2KICx2 1x2 13 200-240V200-240V or 380-440V 2.0 2 3 20 260
TPH8T3KICx2 2x2 13 200-240V200-240V or 380-440V 3.0 2 3 30 260
TPH8T4KICx2 3x2 13 200-240V200-240V or 380-440V 4.0 2 3 40 260
TPH8T5KICx2 3x2 13 200-240V200-240V or 380-440V 5.0 2 3 50 230
TPH12T2KICx2 2x2 13 200-240V200-240V or 380-440V 2.0 2 3 20 460
TPH12T3KICx2 3x2 13 200-240V200-240V or 380-440V 3.0 2 3 30 460
TPH12T4KICx2 5x2 3 200-240V or 380-440V 4.0 2 3 40 460
TPH25T2KICx2 5x2 3 200-240V or 380-440V 2.0 3 4 20 830
TPH25T3KICx2 5x2 3 200-240V or 380-440V 3.0 3 4 30 830
TPH25T4KICx2 7½x2 3 200-240V or 380-440V 4.0 3 4 40 830
TPH25T5KICx2 10x2 3 200-240V or 380-440V 5.0 3 4 50 830
TPH25T6KICx2 10x2 3 200-240V or 380-440V 6.0 3 4 60 830

Dimensions (mm)

TPH2T/4T - ICx2
Model A B Pressure tank(L)
TPH2T2KICx2 306 99 0.8x2
TPH2T3KICx2 324 117 0.8x2
TPH2T4KICx2 342 135 0.8x2
TPH2T5KICx2 400 153 0.8x2
TPH2T6KICx2 418 171 0.8x2
TPH4T2KICx2 315 108 0.8x2
TPH4T3KICx2 382 135 0.8x2
TPH4T4KICx2 409 162 0.8x2
TPH4T5KICx2 436 189 0.8x2
TPH4T6KICx2 494 216 0.8x2
TPH8T/12T - ICx2
Model A B Pressure tank(L)
TPH8T2KICx2 376.5 75 12 x2
TPH8T3KICx2 408.5 107 12 x2
TPH8T4KICx2 435.5 107 12 x2
TPH8T5KICx2 469.5 141 12 x2
TPH12T2KICx2 376.5 75 12 x2
TPH12T3KICx2 435.5 107 12 x2
TPH12T4KICx2 435.5 107 12 x2
TPH25T - ICx2
Model A B Pressure tank(L)
TPH25T2KICx2 536 118 12x2
TPH25T3KICx2 596 178 12x2
TPH25T4KICx2 596 178 12x2
TPH25T5KICx2 706 238 12x2
TPH25T6KICx2 706 238 12x2
 

i.Catalog

Catalog

TPHICx2 Constant Pressure Inverter Control System

Updated on 2024/03/29

1.68 MB

ii.Instruction Manual

Instruction Manual

TPHICx2 Constant Pressure Inverter Control System

Updated on 2024/03/29

2.47MB

Thank you TPHICx2 products !

Go Back
0

Product List Product
Comparison

Product List(0)

Select up to10 products; 0selected

Compare

WALRUS-AI

Contact

繁體中文

接受 拒絕

請勾選了解並同意說明內容

OK