For Commercial Use
TPHICx2
Constant Pressure Inverter Control System
TPHICx2
TPHICx2

Apartment buildings, houses, villa water supply, factories, water supply systems, drinking water systems, RO water treatment equipment, supermarkets, motels, SPA, etc.



Product Description

Applications

Apartment buildings, houses, villa water supply, factories, water supply systems, drinking water systems, RO water treatment equipment, supermarkets, motels, SPA, etc.

Product Features

The pump will start smoothly when water is consumed. The inverter controller has a pressure sensor to detect down-stream pressure and adjust the motor speed to keep it at the required psi.


Constant and stable pressure control:The pump will maintain a constant operating pressure at the pressure setting. This ensures a stable water supply even though occasionally the output .ow is over the capacity.

Dry-run protection: The pump will automatically shut down to protect against dry running. Once the pump starts to operate, the pressure sensor will automatically detect the pressure limit.

Automatic stop when flow stops: The pump will automatically cycle down as water usage decreases. 

Pressure compensation for pipeline leaks: Should the down steam pressure drop due to leaks in the piping system, the microcomputer will detect the pressure loss automatically and operate the pump to maintain the pressure setting limit.

Single or parallel unit operation: Parallel operation: When water usage is low, one unit will begin to operate until the water usage increases, when it can no longer handle the required water pressure, the other unit will start functioning in parallel. The duplex unit will switch to single unit operation automatically with the decrease in water demand. 

Interchangeable operation: When a pump has operated through the preset interval (adjustable at 0-24 hours) the system will automatically switch to the other unit. This cycle will continue through time.

 
 Operation Condition

1. Ambient temperature:Max. +40°C

2. Liquid temperature:+4°C~+40°C

3. Suitable liquids:Potable water or other clean, thin or non-aggressive liquids

4. Inlet pressure: Lower than the constant pressure setting limit (see page 03~08)

5.System Pressure:Max.10kg/cm²

 

Speicifation

Model

Inverter ControllerOutput Power

(HP)

Phrase

(Ø)

Voltage

(V)

Pre-set Pressure

(kg/cm²) 

Inlet

(in.)

Outlet

(in.)

Nominal Set Head

(M)

Nominal Set FLow

(L/min)

TPH2T2K ICx2 1 x2 200-240V 2.0 1 2 20 60
3Ø 200-240V or 380-440V
TPH2T3K ICx2 x2 200-240V 3.0 1 2 30 60
3Ø 200-240V or 380-440V
TPH2T4K ICx2 x2 200-240V 4.0 1 2 40 60
3Ø 200-240V or 380-440V
TPH2T5K ICx2 x2 200-240V 5.0 1 2 50 60
3Ø 200-240V or 380-440V
TPH2T6K ICx2 x2 200-240V 6.0 1 2 60 60
3Ø 200-240V or 380-440V

 

Model

Inverter Controller Output PowerOutput Power

(HP)

Phrase

(Ø)

Voltage

(V)

Pre-set Pressure

(kg/cm²) 

Inlet

(in.)

Outlet

(in.)

Nominal Set Head

(M)

Nominal Set FLow

(L/min)

TPH4T2K ICx2 x2 200-240V 2.0 1½ 2 20 120
3Ø 200-240V or 380-440V
TPH4T3K ICx2 x2 200-240V 3.0 1½ 2 30 120
3Ø 200-240V or 380-440V
TPH4T4K ICx2 x2 200-240V 4.0 1½ 2 40 120
3Ø 200-240V or 380-440V
TPH4T5K ICx2 x2 200-240V 5.0 1½ 2 50 120
3Ø 200-240V or 380-440V
TPH4T6K ICx2 x2 200-240V 6.0 1½ 2 60 120
3Ø 200-240V or 380-440V

 

 
Model

Inverter Controller Output PowerOutput Power

(HP)

Phrase

(Ø)

Voltage

(V)

Pre-set Pressure

(kg/cm²) 

Inlet

(in.)

Outlet

(in.)

Nominal Set Head

(M)

Nominal Set FLow

(L/min)

TPH8T2K ICx2 x2 200-240V 2.0 2 3 20 260
3Ø 200-240V or 380-440V
TPH8T3K ICx2 x2 200-240V 3.0 2 3 30 260
3Ø 200-240V or 380-440V
TPH8T4K ICx2
x2 200-240V 4.0 2 3 40 260
200-240V or 380-440V
TPH8T5K ICx2 x2 1Ø 200-240V 5.0 2 3 50 230
200-240V or 380-440V

 

Model

Inverter Controller Output PowerOutput Power

(HP)

Phrase

(Ø)

Voltage

(V)

Pre-set Pressure

(kg/cm²) 

Inlet

(in.)

Outlet

(in.)

Nominal Set Head

(M)

Nominal Set FLow

(L/min)

TPH12T2K ICx2 x2 200-240V 2.0 2 3 20 460
3Ø 200-240V or 380-440V
TPH12T3K ICx2 x2 200-240V 3.0
2 3 30 460
200-240V or 380-440V
TPH12T4K ICx2 x2 200-240V or 380-440V 4.0 2 3 40 460

 

Model

Inverter Controller Output PowerOutput Power

(HP)

Phrase

(Ø)

Voltage

(V)

Pre-set Pressure

(kg/cm²) 

Inlet

(in.)

Outlet

(in.)

Nominal Set Head

(M)

Nominal Set FLow

(L/min)

TPH25T2K ICx2 x2 3Ø 200-240V or 380-440V 2.0 3 4 20 830
TPH25T3K ICx2 x2 200-240V or 380-440V 3.0 3 4 30 830
TPH25T4K ICx2 7½ x2 200-240V or 380-440V 4.0 3 4 40 830
TPH25T5K ICx2 10 x2 200-240V or 380-440V 5.0 3 4 50 830
TPH25T6K ICx2 10 x2 200-240V or 380-440V 6.0 3 4 60 830

 

Model

Inverter Controller Output PowerOutput Power

(HP)

Phrase

(Ø)

Voltage

(V)

Pre-set Pressure

(kg/cm²) 

Inlet

(in.)

Outlet

(in.)

Nominal Set Head

(M)

Nominal Set FLow

(L/min)

TPH50T2.5K ICx2 7½ x2 200-240V or 380-440V 2.5 4 6 25 1610
TPH50T4K ICx2 10 x2 200-240V or 380-440V 4.0 4 6 40 1610
TPH50T5K ICx2 15 x2 200-240V or 380-440V 5.0 4 6 50 1610


Model

A

B

Pressure tank (L)

TPH2T2KICx2 306 99 0.8x2
TPH2T3KICx2 324 117 0.8x2
TPH2T4KICx2 342 135 0.8x2
TPH2T5KICx2 400 153 0.8x2
TPH2T6KICx2 418 171 0.8x2
 
TPH4T2KICx2 315 108 0.8x2
TPH4T3KICx2 382 135 0.8x2
TPH4T4KICx2 409 162 0.8x2
TPH4T5KICx2 436 189 0.8x2
TPH4T6KICx2 494 216 0.8x2



Model

A

B

Pressure tank (L)

TPH8T2KICx2 376.5 75 12x2
TPH8T3KICx2 408.5 107 12x2
TPH8T4KICx2 435.5 107 12x2
TPH8T5KICx2 469.5 141 12x2
 
TPH12T2KICx2 376.5 75 12x2
TPH12T3KICx2 435.5 107 12x2
TPH12T4KICx2 435.5 107 12x2




Model

A

B

Pressure tank (L)

Fig

TPH25T2KICx2 536 118 12x2 7
TPH25T3KICx2 596 178 12x2 7
TPH25T4KICx2 596 178 12x2 7
TPH25T5KICx2 706 238 12x2 7
TPH25T6KICx2 706 238 12x2 7
 
TPH50T2.5KICx2 582.5 162 12x2 8
TPH50T4KICx2 692.5 222 12x2 8
TPH50T5KICx2 742.5 222 12x2 8
Download

Catalog

Constant Pressure Inverter Control System

Updated date:2019/07/23

1.52MB

Instruction Manual

TPHICx2 Series Instruction Manual

Updated date:2019/06/27

929KB