For Commercial Use
TPHIC
Constant Pressure Inverter Control System
TPHIC
TPHIC

Apartment buildings, houses, villa water supply, factories, water supply systems, drinking water systems, RO water treatment equipment, supermarkets, motels, SPA, etc.



Product Description

Applications

Apartment buildings, houses, villa water supply, factories, water supply systems, drinking water systems, RO water treatment equipment, supermarkets, motels, SPA, etc.

Product Features

The pump will start smoothly when water is consumed. The inverter controller has a pressure sensor to detect down-stream pressure and adjust the motor speed to keep it at the required psi.


Constant and stable pressure control:The pump will maintain a constant operating pressure at the pressure setting. This ensures a stable water supply even though occasionally the output .ow is over the capacity.

Dry-run protection: The pump will automatically shut down to protect against dry running. Once the pump starts to operate, the pressure sensor will automatically detect the pressure limit.

Automatic stop when flow stops: The pump will automatically cycle down as water usage decreases. 

Pressure compensation for pipeline leaks: Should the down steam pressure drop due to leaks in the piping system, the microcomputer will detect the pressure loss automatically and operate the pump to maintain the pressure setting limit.

Single or parallel unit operation: Parallel operation: When water usage is low, one unit will begin to operate until the water usage increases, when it can no longer handle the required water pressure, the other unit will start functioning in parallel. The duplex unit will switch to single unit operation automatically with the decrease in water demand. 

Interchangeable operation: When a pump has operated through the preset interval (adjustable at 0-24 hours) the system will automatically switch to the other unit. This cycle will continue through time.

 
 Operation Condition

1. Ambient temperature:Max. +40°C

2. Liquid temperature:+4°C~+40°C

3. Suitable liquids:Potable water or other clean, thin or non-aggressive liquids

4. Inlet pressure: Lower than the constant pressure setting limit (see page 12~17)

 

Specification

Model

Inverter Controller Output Power

(HP)

Prase

(Ø)

Voltage

(V)

Pre-set Pressure

(kg/cm²) 

Inlet

(in.)

Outlet

(in.)

Nominal Set Head

(M)

Nominal Set Flow

(L/min)

TPH2T2KIC 1 200-240V 2.0 1 1 20 30
3Ø 200-240V or 380-440V
TPH2T3KIC 1 200-240V 3.0 1 1 30 30
3Ø 200-240V or 380-440V
TPH2T4KIC 1 200-240V 4.0 1 1 40 30
3Ø 200-240V or 380-440V
TPH2T5KIC 1 200-240V 5.0 1 1 50 30
3Ø 200-240V or 380-440V
TPH2T6KIC 1 200-240V 6.0 1 1 60 30
3Ø 200-240V or 380-440V

 

Model

Inverter Controller Output Power

(HP)

Phrase

(Ø)

Voltage

(V)

Pre-set Pressure

(kg/cm²) 

Inlet

(in.)

Outlet

(in.)

Nominal Set Head

(M)

Nominal Set Flow

(L/min)

TPH4T2KIC 1 200-240V 2.0 1½ 1½ 20 60
3Ø 200-240V or 380-440V
TPH4T3KIC 1 200-240V 3.0 1½ 1½ 30 60
3Ø 200-240V or 380-440V
TPH4T4KIC 2 200-240V 4.0 1½ 1½ 40 60
3Ø 200-240V or 380-440V
TPH4T5KIC 2 200-240V 5.0 1½ 1½ 50 60
3Ø 200-240V or 380-440V
TPH4T6KIC 2 200-240V 6.0 1½ 1½ 60 60
3Ø 200-240V or 380-440V

 

 
Model

Inverter Controller Output Power

(HP)

Phrase

(Ø)

Voltage

(V)

Pre-set Pressure

(kg/cm²) 

Inlet

(in.)

Outlet

(in.)

Nominal Set Head

(M)

Nominal Set Flow

(L/min)

TPH8T2KIC 1 200-240V 2.0 2 2 20 130
3Ø 200-240V or 380-440V
TPH8T3KIC 2 200-240V 3.0 2 2 30 130
3Ø 200-240V or 380-440V
TPH8T4KIC
3 200-240V 4.0 2 2 40 130
200-240V or 380-440V
TPH8T5KIC 3 1Ø 200-240V 5.0 2 2 50 115
200-240V or 380-440V

 

Model 

Inverter Controller Output Power

(HP)

Phrase

(Ø)

Voltage

(V)

Pre-set Pressure

(kg/cm²) 

Inlet

(in.)

Outlet

(in.)

Nominal Set Head

(M)

Nominal Set Flow

(L/min)

TPH12T2KIC 2 200-240V 2.0 2 2 20 230
3Ø 200-240V or 380-440V
TPH12T3KIC 3 200-240V 3.0
2 2 30 230
200-240V or 380-440V
TPH12T4KIC 5 200-240V or 380-440V 4.0 2 2 40 230

 

Model

Inverter Controller Output Power

(HP)

Phrase

(Ø)

Voltage

(V)

Pre-set Pressure

(kg/cm²) 

Inlet

(in.)

Outlet

(in.)

Nominal Set Head

(M)

Nominal Set Flow

(L/min)

TPH25T2KIC 5 3Ø 200-240V or 380-440V 2.0 3 3 20 415
TPH25T3KIC 5 200-240V or 380-440V 3.0 3 3 30 415
TPH25T4KIC 200-240V or 380-440V 4.0 3 3 40 415
TPH25T5KIC 10 200-240V or 380-440V 5.0 3 3 50 415
TPH25T6KIC 10 200-240V or 380-440V 6.0 3 3 60 415

 

Model

Inverter Controller Output Power

(HP)

Phrase

(Ø)

Voltage

(V)

Pre-set Pressure

(kg/cm²) 

Inlet

(in.)

Outlet

(in.)

Nominal Set Head

(M)

Nominal Set Flow

(L/min)

TPH50T2.5KIC 200-240V or 380-440V 2.5 4 4 25 810
TPH50T4KIC 10 200-240V or 380-440V 4.0 4 4 40 810
TPH50T5KIC 15 200-240V or 380-440V 5.0 4 4 50 810


Model

A

B

C

D

E

H

Pressure tank (L)

Fig

TPH2T2KIC 306 114 99 90 267 357 0.8 1
TPH2T3KIC 324 132 117 90 267 357 0.8 1
TPH2T4KIC 342 150 135 90 267 357 0.8 1
TPH2T5KIC 400 168 153 90 267 357 0.8 1
TPH2T6KIC 418 186 171 90 267 357 0.8 1
 
TPH2T2KICV 589 114 99 130 181 596 0.8 2
TPH2T3KICV 607 132 117 130 181 596 0.8 2
TPH2T4KICV 625 150 135 130 181 596 0.8 2
TPH2T5KICV 643 168 153 130 181 596 0.8 2
TPH2T6KICV 661 186 171 130 181 596 0.8 2
 
TPH4T2KIC 315 123 108 90 238 328 0.8 1
TPH4T3KIC 382 150 135 90 238 328 0.8 1
TPH4T4KIC 409 177 162 90 238 328 0.8 1
TPH4T5KIC 436 204 189 90 238 328 0.8 1
TPH4T6KIC 494 231 216 90 238 328 0.8 1
 
TPH4T2KICV 598 123 108 130 153 596 0.8 2
TPH4T3KICV 625 150 135 130 153 596 0.8 2
TPH4T4KICV 652 177 162 130 153 596 0.8 2
TPH4T5KICV 679 204 189 130 153 596 0.8 2
TPH4T6KICV 706 231 216 130 153 596 0.8 2



Model

A

B

C

D

E

H

Pressure tank (L)

Fig

TPH8T2KIC 603.5 128.5 75 151 235 625 4 3
TPH8T3KIC 635 160 107 151 235 625 4 3
TPH8T4KIC 635 160 107 151 235 625 4 3
TPH8T5KIC 669 194 141 151 235 625 4 3
 
TPH12T2KIC 603.5 128.5 75 151 235 625 4 3
TPH12T3KIC 635 160 107 151 235 625 4 3
TPH12T4KIC 635 160 107 151 235 625 4 3





Model

A

B

C

Pressure tank (L)

Fig

TPH25T2KIC 821 231 118 4 4
TPH25T3KIC 881 291 178 4 4
TPH25T4KIC 596 178 57 4 5
TPH25T5KIC 706 238 117 4 5
TPH25T6KIC 706 238 117 4 5
 
TPH50T2.5KIC 583 162 43 12 6
TPH50T4KIC 693 222 103 12 6
TPH50T5KIC 743 222 103 12 6




Download

Catalog

Constant Pressure Inverter Control System

Updated date:2015/06/03

892KB

Instruction Manual

TPHIC Series Instruction Manual

Updated date:2015/06/03

262KB